Gas: Hydrogen
Maximum Flow Rate: 80.00 std. L/min
Housing Material: Stainless Steel
Seals: Viton-A® (Standard)
Fittings: 1/4 inch compression
Display: LCD readout display
Power Input: 12 VDC
Input/Output Signal: 0-5 VDC / 0-5 VDC
ACCURACY (including linearity):
±1.5% of full scale, including linearity for gas temperatures of 59 FF to 77 FF (15 FC to 25 FC) and pressures of 5 to 60 psia (0.4 to 4.1 bars). Optional ±1% of full scale (certified calibration accuracy) associated with a given set of temperature and pressure values.
REPEATABILITY:
±0.5% of full scale.
RESPONSE TIME:
Generally 2 seconds to within ±2% of actual flow rate over 25 to 100% of full scale.
TEMPERATURE COEFFICIENT:
0.15% of full scale / FC.
PRESSURE COEFFICIENT:
0.01% of full scale / psi (0.07 bar).
PRESSURE DROP:
See table 5.
OPTIMUM GAS PRESSURE:
25 psig (1.73 bars).
MAX GAS PRESSURE:
1000 psig (70 bars) maximum GFC 17, 37, 47. 500 psig (34.5 bars) GFC 57, 67, 77.
MAX DIFF. PRESSURE:
GFC 17, 37, 57, 67, and 77 50 psi (3.4 bars), GFC 47, 40 psi (2.7 bars).
GAS and AMBIENT TEMP:
41 FF to 122 FF (5 FC to 50 FC).
**MATERIALS FLUID CONTACT:
a. Aluminum models GFC Series: anodized aluminum, 316 stainless steel, brass and Viton7 O-rings.
b. Stainless Steel models GFC17S, 37S, 47S, 57S, 67S and 77S: 316 stainless steel and Viton7 O-rings.
Optional O-rings: Buna, EPR and Kalrez7.
ATTITUDE SENSITIVITY:
No greater than +15 degree rotation from horizontal to vertical; standard calibration is in horizontal position.
OUTPUT SIGNALS:
Linear 0-5 Vdc. (1000 ohms min. load impedance); 4-20 mA (0-500 ohms loop resistance) Max noise ±20mV.
COMMAND SIGNALS:
Analog 0-5 Vdc or 4-20 mA for remote set point mode; NPN compatible purge /valve off.
CONNECTIONS:
GFC 17 and 37: 1/4” compression fittings. Optional: 1/4” VCR7, 1/8”or 3/8 compression fittings (GFC17).
GFC 47: 3/8” compression fittings.
GFC 57: 3/8” compression fittings.
GFC 67: 1/2” compression fittings.
GFC 77: 3/4” FNPT fittings. Optional: 3/4” compression fittings (GFC77).
LEAK INTEGRITY:
1 x 10-7 smL/sec of helium maximum to the outside environment.
TRANSDUCER INPUT POWER:
+12 Vdc, 800 mA; +24 Vdc, 650 mA optional.
CIRCUIT PROTECTION:
Circuit boards have built-in polarity reversal protection. Resettable fuses provide power input protection.
DISPLAY:
3-1/2 digit LCD, 0.5” high characters.
CE COMPLIANT:
EN 55011 class 1, class B; EN50082-1.