MicroKnowz™Neodym Technologies Inc.Lead Time: 14 daysContact us for pricing | | Image Viewer (Click on image for detailed view) |
| | | |  | Specification Information |  |
MicroKnowz™ Details:Warning & Alarm Levels
· Alarm & warning PPMs specified at order time
· Alarm level from 10-75% of reading range
· Warning level/action is optional
· Warning level from 20-80% of alarm level
· Levels are field-adjustable via PK-Port™
State Indications· Normal, warning, alarm & error state
· Errors-as-Alarms for fail safe operation
· Live monitoring & data logging via PK-Port
Reliability Features· Optional alarm-producing errors
· Sensor failure & disconnection detection
· Overdose/saturation damage detection
· Temperature out-of-bounds detection
· Digital calibration values delimited
· Low supply voltage inhibit
· Power fail detect via signal offset loss
· Watchdog timer & software checksums
Environmental Requirements· Diffusion sampling
· 3 meters/second flow rate maximum
· 10% minimum atmospheric oxygen
· 10% to 95% R.H. (non-condensing) oper.
· 0.8 to 1.2 Atmosphere operating pressure
Calibration· All devices individually calibrated
· FLASH-based cal. accessible via PK-Port
· Do not use desiccated (0% R.H.) cal gas
· Six month recalib. schedule recommended
· Periodic factory recertification avail.
Incompatible Uses· Not for use in anaerobic environments
· No dusty or corrosive environments
· No condensing moisture
· Not for use with desiccated calibration gas
· No butane gas bump-testing
· Adversely affected by silicone vapors
· Very high gas levels may damage sensor
PK-Port Interface· Access via interface connector pin
· PC (serial) interface module extra
· Real-time monitoring and data-logging
· Access/modify config. & cal. values
Mechanical· Enclosure size: 33 x 23 x 29 mm
· Flanges: 9mm wide with 4mm holes
· Weight: 15 g
| PARAMETER |
HYDROGEN |
METHANE |
PROPANE |
COMMENT |
| Model: |
MK-GH |
MK-GM |
MK-GP |
Part number lead-in |
| Sensor Type: |
MOS |
MOS |
MOS |
|
| Range: |
0-20,000 |
0-25,000 |
0-10,000 |
Parts-per-million (PPM) |
| Resolution: |
100 PPM |
100 PPM |
50 PPM |
Logical internal resolution |
| Accuracy (typ): |
+/- 800 |
+/- 800 |
+/- 300 |
at 65% R.H. |
| Response Time: |
4 |
4 |
4 |
Seconds to T90 |
| Recovery Time: |
10 |
10 |
10 |
Seconds to T10 |
| Oper. Temp: |
-40 to +80 |
-40 to +80 |
-40 to +80 |
Deg. C., Active comp. |
| Oper. Humidity: |
10-95 |
10-95 |
10-95 |
% R.H., non-condensing |
| Start-up Time: |
30 |
30 |
30 |
Seconds (warm-up time) |
| Power Consum: |
375 / 600 |
375 / 600 |
375 / 600 |
mW at 5 VDC / 12 VDC |
| Alarm Points: |
2K-15K |
2.5K-18K |
1K-7.5K |
PPM, FLASH memory-based. |
| Overdose Detect: |
100,000 |
125,000 |
40,000 |
PPM, approximate |
| PK-Port Monitor: |
Yes |
Yes |
Yes |
Digital config./monitor |
|
|  | |  |  |
|
|  | H-Tech Warranty & Guarantee |  |
H-Tech will work directly with you to address any manufacturer defects or other warranty issues in order to resolve any problem quickly and efficiently with minimum consumer effort.
H-Tech's Warranty Policy |
|  | |  |  |
|
|  | H-Tech Shipping Information |  |
• Estimated Ship Dimensions: " x " x " • Estimated Ship Weight: lbs • Lead time: 14 days • Shipping origin: Vancouver, Canada Please contact us for pricing on this product. H-Tech's Shipping Policy |
|  | |  |  |
|
|  |
|
|
|
|
©2008 Neodym Technologies Inc. - All Rights Reserved