Panterra SensorNeodym Technologies Inc.Lead Time: 14 daysContact us for pricing | | Image Viewer (Click on image for detailed view) |
| | | |  | Specification Information |  |
- One common interface for several sensor/gas types
- 10-bit auto-ranging sensor sampling system
- Normal, Warning, Alarm & Error states
- Bi-color LED status indicator
- Optional NO or NC dry relay
- Auto-resetting or latching operation
- Optional 0-to-5V proportional output (10 bits)
- Optional binary operation (TTL output)
- Optional voltage encoded state output (analog)
- Optional alarm beeper
- PK-Port™ compatible digital communications
- User-settable alarm/warning via PK-Port™
- Digital FLASH-based calibration
- Each device factory pre-calibrated
- Field re-programmable firmware
- Active temperature compensation (as required)
- Sensor & temperature error detection
- Optional extendable sensor head
- 5VDC, 7-40VDC or 7-60VDC input power
- 500 mW operating power (typical)
Action Level Options:
Alarm level specified as "PN-Sx-Gyy-Annn", where:
"x" is the sensor type code (EG "ST" denotes thermal conductivity)
"yy" is the target gas code (EG "GOX" implies oxygen)
"nnn" is alarm level (% of sensing range)
Warning level specified as "Wpp" where "pp" is percentage of sensing range
Error Handling Options:
1. Audio-visual indication of errors [E1]
2. Errors trigger alarms (fail safe) [E2]
Overdose Handling Options:
(Applies to MOS hydrogen sensor only)
1. Failure to hypersensitivity [X1]
2. Failure to persistent error state [X2]
Output Signal Option:
1. TTL - Norm.-high, Auto (self-clearing) [O1]
2. TTL - Norm.-low, Auto (self-clearing) [O2]
3. TTL - Norm.-high, Latch (Button reset) [O3]
4. TTL - Norm.-low, Latch (Button reset) [O4]
5. Proportional output - 0 to 5VDC [O5]
0.5V safety offset (zero reading)
1000 steps of 4.9mV each
Each step equals one resolution unit
6. State step - 0 to 5VDC [O6]
Relay Options
1. Relay not required [R0]
2. Normally-closed, Auto (self-clearing) [R1]
3. Normally-open, Auto (self-clearing) [R2]
4. Normally-closed, Latch (Button reset) [R3]
5. Normally-open, Latch (Button reset) [R4]
Specify relay to respond to warning state, alarm state, or both.
Audio Sounder Options
1. No beeper [S0]
2. Included beeper [S1]
Enclosure Options
1. Open-frame (Circuit board only) [P0]
2. Anodized aluminum case (No flange) [P1]
3. Anodized aluminum case (With flange) [P2]
Sensor Placement Options
Sensor heads can be housed within the control unit or can be extended via a cable. Extended sensors are house in a flanged aluminum enclosure.
1. No sensor extension [L0]
2. Sensor extended "n" meters [Ln]
Powering Options
1. 5 VDC (+/- 5%) [I1]
2. 7-to-40 VDC switch mode PSU [I2]
3. 7-to-60 VDC switch mode PSU [I3] |
|  | |  |  |
|
|  | H-Tech Warranty & Guarantee |  |
H-Tech will work directly with you to address any manufacturer defects or other warranty issues in order to resolve any problem quickly and efficiently with minimum consumer effort.
H-Tech's Warranty Policy |
|  | |  |  |
|
|  | H-Tech Shipping Information |  |
• Estimated Ship Dimensions: " x " x " • Estimated Ship Weight: lbs • Lead time: 14 days • Shipping origin: Vancouver, Canada Please contact us for pricing on this product. H-Tech's Shipping Policy |
|  | |  |  |
|
|  |
|
|
|
|
©2008 Neodym Technologies Inc. - All Rights Reserved